-- REDSTONE-ATM-MIB
--
-- Redstone Communications Inc. Enterprise MIB
-- ATM MIB
--
-- Copyright 1998 Redstone Communications, Incorporated.
-- All Rights Reserved.
-- *****************************************************************REDSTONE-ATM-MIB DEFINITIONS::=BEGINIMPORTSMODULE-IDENTITY,OBJECT-TYPE,Integer32,Counter64,Counter32FROM SNMPv2-SMI
RowStatusFROM SNMPv2-TC
InterfaceIndex,InterfaceIndexOrZeroFROM IF-MIB
rsMgmt
FROM REDSTONE-SMI
RsNextIfIndex
FROM REDSTONE-TC;rsAtmMIB MODULE-IDENTITYLAST-UPDATED"200008020000Z"ORGANIZATION"Redstone Communications, Inc."CONTACT-INFO"
Redstone Communications, Inc.
5 Carlisle Road
Westford MA 01886
USA
Tel: +1-978-692-1999
Email: mib@redstonecom.com
"DESCRIPTION"Added the rsAtmCirciotOamStatisticsTable"REVISION"200008020000Z"DESCRIPTION"Added the rsAtmPvcStatisticsTable"REVISION"0001130000Z"DESCRIPTION"Initial version of this MIB module."::={ rsMgmt 8}
-- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Textual conventions
-- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++-- No textual conventions are defined in this MIB.-- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Managed objects
-- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++rsAtmObjects OBJECTIDENTIFIER::={ rsAtmMIB 1}--
-- This MIB contains managed objects for each of three interface
-- layers: ATM; AAL5; and ATM Subinterface. For each of these layers,
-- management objects are provided to query for an available
-- interface index, and to create/delete interfaces of that type.
-- Creating/deleting these interface types using this MIB has
-- the side effect of creating/deleting corresponding entries
-- in the Interface MIB ifTable/ifXTable, and in the Redstone
-- Enterprise Interface MIB rsIfTable.
--rsAtmIfLayer OBJECTIDENTIFIER::={ rsAtmObjects 1}rsAtmAal5IfLayer OBJECTIDENTIFIER::={ rsAtmObjects 2}rsAtmSubIfLayer OBJECTIDENTIFIER::={ rsAtmObjects 3}-- //////////////////////////////////////////////////////////////////////
--
-- ATM LAYER
--
-- //////////////////////////////////////////////////////////////////////--
-- IfIndex selection for creating new ATM interfaces
--rsAtmNextIfIndex OBJECT-TYPE
SYNTAX RsNextIfIndex
MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Coordinate ifIndex value allocation for entries
in rsAtmIfTable.
A GET of this object returns the next available ifIndex
value to be used to create an entry in the associated
interface table; or zero, if no valid ifIndex value is
available. This object also returns a value of zero when
it is the lexicographic successor of a varbind presented
in an SNMP GETNEXT or GETBULK request, for which circumstance
it is assumed that ifIndex allocation is unintended.
Successive GETs will typically return different
values, thus avoiding collisions among cooperating
management clients seeking to create table entries
simultaneously.
"::={ rsAtmIfLayer 1}--
-- The ATM Interface Table
--rsAtmIfTable OBJECT-TYPESYNTAXSEQUENCEOF RsAtmIfEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"This table contains entries for ATM interfaces present in the system."::={ rsAtmIfLayer 2}rsAtmIfEntry OBJECT-TYPESYNTAX RsAtmIfEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"Each entry describes the characteristics of an ATM interface.
Creating/deleting entries in this table causes corresponding
entries for be created /deleted in ifTable/ifXTable/rsIfTable."INDEX{ rsAtmIfIndex }::={ rsAtmIfTable 1}
RsAtmIfEntry ::=SEQUENCE{
rsAtmIfIndex
InterfaceIndex,
rsAtmIfRowStatus
RowStatus,
rsAtmIfLowerIfIndex
InterfaceIndexOrZero,
rsAtmIfIlmiVpi
Integer32,
rsAtmIfIlmiVci
Integer32,
rsAtmIfIlmiVcd
Integer32,
rsAtmIfIlmiPollFrequency
Integer32,
rsAtmIfIlmiAdminState
INTEGER,
rsAtmIfUniVersion
INTEGER,
rsAtmIfOamCellRxAdminState
INTEGER}rsAtmIfIndex OBJECT-TYPESYNTAXInterfaceIndexMAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"The ifIndex of the ATM interface. When
creating entries in this table, suitable values
for this object are determined by reading
rsAtmNextIfIndex."::={ rsAtmIfEntry 1}rsAtmIfRowStatus OBJECT-TYPESYNTAXRowStatusMAX-ACCESSread-create
STATUScurrentDESCRIPTION"Controls creation/deletion of entries in this table
according to the RowStatus textual convention,
constrained to support the following values only:
createAndGo
destroy
To create an entry in this table, the following
entry objects MUST be explicitly configured:
rsAtmIfRowStatus
rsAtmIfLowerIfIndex
In addition, when creating an entry the following
conditions must hold:
A value for rsAtmIfIndex must have been determined
previously, by reading rsAtmNextIfIndex.
A corresponding entry in ifTable/ifXTable/rsIfTable is
created/destroyed as a result of creating/destroying an entry
in this table.
"::={ rsAtmIfEntry 2}rsAtmIfLowerIfIndex OBJECT-TYPESYNTAXInterfaceIndexOrZeroMAX-ACCESSread-createSTATUScurrentDESCRIPTION"The ifIndex of an interface over which this ATM interface
is to be layered. A value of zero indicates no layering.
An implementation may choose to require that a nonzero value
be configured at entry creation."::={ rsAtmIfEntry 3}rsAtmIfIlmiVpi OBJECT-TYPESYNTAXInteger32(0..255)MAX-ACCESSread-writeSTATUScurrent
DESCRIPTION"The VPI of the Ilmi of a major ATM interface."DEFVAL{0}::={ rsAtmIfEntry 4}rsAtmIfIlmiVci OBJECT-TYPESYNTAXInteger32(0..65535)MAX-ACCESSread-writeSTATUScurrentDESCRIPTION"The VCI of the Ilmi of a major ATM interface."DEFVAL{16}::={ rsAtmIfEntry 5}rsAtmIfIlmiVcd OBJECT-TYPESYNTAXInteger32(0..65535)MAX-ACCESSread-writeSTATUScurrentDESCRIPTION"An integer identifier for the Ilmi, used in conjunction
with the command-line interface.
The value must be unique among VCs configured on the same
ATM interface.
"DEFVAL{0}::={ rsAtmIfEntry 6}rsAtmIfIlmiPollFrequency OBJECT-TYPESYNTAXInteger32
MAX-ACCESSread-writeSTATUScurrentDESCRIPTION"Use to set the Interim Local Management Interface (ILMI)
keepalive timer. This value sets the allowable time between
POLL PDU transmissions if there are no pending sequence data
PDUs. Use the value 0 to disable ILMI keepalives."::={ rsAtmIfEntry 7}rsAtmIfIlmiAdminState OBJECT-TYPESYNTAXINTEGER{disabled(0),enabled(1)}MAX-ACCESSread-writeSTATUScurrentDESCRIPTION"The administrative status of ILMI in the ATM interface."::={ rsAtmIfEntry 8}rsAtmIfUniVersion OBJECT-TYPESYNTAXINTEGER{version3Dot0(0),version3Dot1(1),version4Dot0(2)}MAX-ACCESSread-writeSTATUScurrentDESCRIPTION
"Use to specify the User Network Interface (UNI) the router
should use when ILMI link auto determination is unsuccesful
or ILMI is disabled."::={ rsAtmIfEntry 9}rsAtmIfOamCellRxAdminState OBJECT-TYPESYNTAXINTEGER{oamCellAdminStateDisabled(0),oamCellAdminStateEnabled(1)}MAX-ACCESSread-writeSTATUScurrentDESCRIPTION"Use to specify the OAM Cell Administrative state on this interface"::={ rsAtmIfEntry 10}-- //////////////////////////////////////////////////////////////////////
--
-- AAL5 LAYER
--
-- //////////////////////////////////////////////////////////////////////--
-- IfIndex selection for creating new ATM AAL5 interfaces
--rsAtmAal5NextIfIndex OBJECT-TYPESYNTAX RsNextIfIndex
MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Coordinate ifIndex value allocation for entries
in rsAtmAal5IfTable.
A GET of this object returns the next available ifIndex
value to be used to create an entry in the associated
interface table; or zero, if no valid ifIndex value is
available. This object also returns a value of zero when
it is the lexicographic successor of a varbind presented
in an SNMP GETNEXT or GETBULK request, for which circumstance
it is assumed that ifIndex allocation is unintended.
Successive GETs will typically return different
values, thus avoiding collisions among cooperating
management clients seeking to create table entries
simultaneously.
"::={ rsAtmAal5IfLayer 1}--
-- The ATM AAL5 Interface Table
--rsAtmAal5IfTable OBJECT-TYPESYNTAXSEQUENCEOF RsAtmAal5IfEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"This table contains entries for ATM AAL5 interfaces present in the system."::={ rsAtmAal5IfLayer 2}rsAtmAal5IfEntry OBJECT-TYPESYNTAX RsAtmAal5IfEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"Each entry describes the characteristics of an ATM AAL5 interface.
Creating/deleting entries in this table causes corresponding
entries for be created /deleted in ifTable/ifXTable/rsIfTable."INDEX{ rsAtmAal5IfIndex }::={ rsAtmAal5IfTable 1}
RsAtmAal5IfEntry ::=SEQUENCE{
rsAtmAal5IfIndex
InterfaceIndex,
rsAtmAal5IfRowStatus
RowStatus,
rsAtmAal5IfLowerIfIndex
InterfaceIndexOrZero}rsAtmAal5IfIndex OBJECT-TYPESYNTAXInterfaceIndexMAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"The ifIndex of the ATM AAL5 interface. When
creating entries in this table, suitable values
for this object are determined by reading
rsAtmAal5NextIfIndex."::={ rsAtmAal5IfEntry 1}rsAtmAal5IfRowStatus OBJECT-TYPESYNTAXRowStatusMAX-ACCESSread-createSTATUScurrentDESCRIPTION"Controls creation/deletion of entries in this table
according to the RowStatus textual convention,
constrained to support the following values only:
createAndGo
destroy
To create an entry in this table, the following
entry objects MUST be explicitly configured:
rsAtmAal5IfRowStatus
rsAtmAal5IfLowerIfIndex
In addition, when creating an entry the following
conditions must hold:
A value for rsAtmAal5IfIndex must have been determined
previously, by reading rsAtmAal5NextIfIndex.
A corresponding entry in ifTable/ifXTable/rsIfTable is
created/destroyed as a result of creating/destroying an entry
in this table.
"::={ rsAtmAal5IfEntry 2}rsAtmAal5IfLowerIfIndex OBJECT-TYPESYNTAXInterfaceIndexOrZero
MAX-ACCESSread-createSTATUScurrentDESCRIPTION"The ifIndex of an ATM interface over which this ATM AAL5 interface
is to be layered. A value of zero indicates no layering.
An implementation may choose to require that a nonzero value
be configured at entry creation."::={ rsAtmAal5IfEntry 3}-- //////////////////////////////////////////////////////////////////////
--
-- ATM SUBINTERFACE LAYER
--
-- //////////////////////////////////////////////////////////////////////--
-- IfIndex selection for creating new ATM Subinterfaces
--rsAtmSubIfNextIfIndex OBJECT-TYPESYNTAX RsNextIfIndex
MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Coordinate ifIndex value allocation for entries
in rsAtmSubIfTable.
A GET of this object returns the next available ifIndex
value to be used to create an entry in the associated
interface table; or zero, if no valid ifIndex value is
available. This object also returns a value of zero when
it is the lexicographic successor of a varbind presented
in an SNMP GETNEXT or GETBULK request, for which circumstance
it is assumed that ifIndex allocation is unintended.
Successive GETs will typically return different
values, thus avoiding collisions among cooperating
management clients seeking to create table entries
simultaneously.
"::={ rsAtmSubIfLayer 1}--
-- The ATM Subinterface Table
--rsAtmSubIfTable OBJECT-TYPESYNTAXSEQUENCEOF RsAtmSubIfEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"This table contains entries for ATM Subinterfaces present in the system."::={ rsAtmSubIfLayer 2}rsAtmSubIfEntry OBJECT-TYPESYNTAX RsAtmSubIfEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"Each entry describes the characteristics of an ATM Subinterface.
Creating/deleting entries in this table causes corresponding
entries for be created /deleted in ifTable/ifXTable/rsIfTable."INDEX{ rsAtmSubIfIndex }::={ rsAtmSubIfTable 1}
RsAtmSubIfEntry ::=SEQUENCE{
rsAtmSubIfIndex
InterfaceIndex,
rsAtmSubIfRowStatus
RowStatus,
rsAtmSubIfDistinguisher
Integer32,
rsAtmSubIfLowerIfIndex
InterfaceIndexOrZero}rsAtmSubIfIndex OBJECT-TYPESYNTAXInterfaceIndexMAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION
"The ifIndex of the ATM Subinterface. When
creating entries in this table, suitable values
for this object are determined by reading
rsAtmSubNextIfIndex."::={ rsAtmSubIfEntry 1}rsAtmSubIfRowStatus OBJECT-TYPESYNTAXRowStatusMAX-ACCESSread-createSTATUScurrentDESCRIPTION"Controls creation/deletion of entries in this table
according to the RowStatus textual convention,
constrained to support the following values only:
createAndGo
destroy
To create an entry in this table, the following
entry objects MUST be explicitly configured:
rsAtmSubIfRowStatus
rsAtmSubIfLowerIndex
In addition, when creating an entry the following
conditions must hold:
A value for rsAtmSubIfIndex must have been determined
previously, by reading rsAtmSubIfNextIfIndex.
A corresponding entry in ifTable/ifXTable/rsIfTable is
created/destroyed as a result of creating/destroying an entry
in this table.
"::={ rsAtmSubIfEntry 2}rsAtmSubIfDistinguisher OBJECT-TYPESYNTAXInteger32MAX-ACCESSread-createSTATUScurrentDESCRIPTION"An integer identifier for the sub interface, used in
conjunction with the command-line interface. It is provided
here for cross-reference purposes only.
The value must be unique among sub interfaces configured on
the same underlying ATM adaptation layer. The upper bound
for the value is further constrained to be identical with
the maximum number of sub interfaces supported by the lower
interface.
If this object is not configured, a value will be allocated
internally and can be queried after table entry creation has
succeeded.
"::={ rsAtmSubIfEntry 3}rsAtmSubIfLowerIfIndex OBJECT-TYPESYNTAXInterfaceIndexOrZeroMAX-ACCESSread-createSTATUScurrentDESCRIPTION"The ifIndex of an ATM AAL5 interface over which this ATM Subinterface
is to be layered. A value of zero indicates no layering.
An implementation may choose to require that a nonzero value
be configured at entry creation."::={ rsAtmSubIfEntry 4}--
-- The ATM Subinterface VCC Table
--rsAtmSubIfVccTable OBJECT-TYPESYNTAXSEQUENCEOF RsAtmSubIfVccEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"This table contains entries for ATM VCCs configured on
ATM Subinterfaces present in the system.
An implementation may constrain the number of VCCs permitted
to be configured per ATM Subinterface; in particular,
an implementation may restrict each ATM Subinterface to
have a single VCC.
Attributes in this entry can only be configured at entry creation,
and remain fixed for the lifetime of the entry.
"::={ rsAtmSubIfLayer 3}rsAtmSubIfVccEntry OBJECT-TYPESYNTAX RsAtmSubIfVccEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"Each entry describes the characteristics of an ATM Subinterface VCC."INDEX{ rsAtmSubIfIndex, rsAtmSubIfVccVpi, rsAtmSubIfVccVci }::={ rsAtmSubIfVccTable 1}
RsAtmSubIfVccEntry ::=SEQUENCE{
rsAtmSubIfVccVpi
Integer32,
rsAtmSubIfVccVci
Integer32,
rsAtmSubIfVccRowStatus
RowStatus,
rsAtmSubIfVccVcd
Integer32,
rsAtmSubIfVccType
INTEGER,
rsAtmSubIfVccServiceCategory
INTEGER,
rsAtmSubIfVccPcr
Integer32,
rsAtmSubIfVccScr
Integer32,
rsAtmSubIfVccMbs
Integer32}rsAtmSubIfVccVpi OBJECT-TYPESYNTAXInteger32(0..255)MAX-ACCESSnot-accessibleSTATUScurrent
DESCRIPTION"The VPI of the ATM VCC used by this subinterface."::={ rsAtmSubIfVccEntry 1}rsAtmSubIfVccVci OBJECT-TYPESYNTAXInteger32(0..65535)MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"The VCI of the ATM VCC used by this subinterface."::={ rsAtmSubIfVccEntry 2}rsAtmSubIfVccRowStatus OBJECT-TYPESYNTAXRowStatusMAX-ACCESSread-createSTATUScurrentDESCRIPTION"Controls creation/deletion of entries in this table
according to the RowStatus textual convention,
constrained to support the following values only:
createAndGo
destroy
To create an entry in this table, the following
entry objects MUST be explicitly configured:
rsAtmSubIfVccRowStatus
In addition, when creating an entry the following
conditions must hold:
The ATM Subinterface identified by rsAtmSubIfIndex must exist.
A positive value configured for rsAtmSubIfVccVcd must not
already be assigned to an existing VCC.
For each value of rsAtmSubIfVccServiceCategory, additional
dependent objects in the entry require configuration as
identified here:
rsAtmSubIfVccServiceCategory Requires configuration of:
------------------------------------------------------------
ubr <none>
ubrPcr rsAtmSubIfVccPcr
nrtVbr rsAtmSubIfVccPcr
rsAtmSubIfVccScr
rsAtmSubIfVccMbs
cbr rsAtmSubIfVccPcr
------------------------------------------------------------
Attributes in this entry can only be configured at entry creation,
and remain fixed for the lifetime of the entry.
"::={ rsAtmSubIfVccEntry 3}rsAtmSubIfVccVcd OBJECT-TYPESYNTAXInteger32(0..65535)MAX-ACCESSread-createSTATUScurrentDESCRIPTION"An integer identifier for the circuit, used in conjunction
with the command-line interface. It is provided here for
cross-reference purposes only.
The value must be unique among VCCs configured on the same
underlying ATM interface. The upper bound for the value is
further constrained to be identical with the maximum number
of VCCs supported by the underlying ATM interface.
If this object is not configured, or is configured with a
value of zero, a value will be allocated internally and can
be queried after table entry creation has succeeded.
"::={ rsAtmSubIfVccEntry 4}rsAtmSubIfVccType OBJECT-TYPESYNTAXINTEGER{
rfc1483VcMux(0),rfc1483Llc(1)}MAX-ACCESSread-createSTATUScurrentDESCRIPTION"Specifies the encapsulation used by the circuit
to carry IP datagrams. Encapsulations are as specified
in RFC1483 Multiprotocol Interconnect over ATM."DEFVAL{ rfc1483VcMux }::={ rsAtmSubIfVccEntry 5}rsAtmSubIfVccServiceCategory OBJECT-TYPESYNTAXINTEGER{ubr(0),ubrPcr(1),nrtVbr(2),cbr(3)}MAX-ACCESSread-createSTATUScurrentDESCRIPTION"Service category for this circuit:
ubr Unspecified bit rate (best effort).
ubrPcr Unspecified Bit Rate with Peak Cell Rate limit.
nrtVbr Non-realtime Variable Bit Rate.
cbr Constant bit rate.
"DEFVAL{ ubr }
::={ rsAtmSubIfVccEntry 6}rsAtmSubIfVccPcr OBJECT-TYPESYNTAXInteger32UNITS"cells per second"MAX-ACCESSread-createSTATUScurrentDESCRIPTION"Peak Cell Rate, in cells per second, of this circuit.
This parameter is only required when rsAtmSubIfVccServiceCategory
is configured to have one of the following values:
ubrPcr
nrtVbr
cbr
"DEFVAL{0}::={ rsAtmSubIfVccEntry 7}rsAtmSubIfVccScr OBJECT-TYPESYNTAXInteger32UNITS"cells per second"MAX-ACCESSread-createSTATUScurrentDESCRIPTION"Sustained Cell Rate, in cells per second, of this circuit.
This parameter is only required when rsAtmSubIfVccServiceCategory
is configured to have one of the following values:
nrtVbr
"DEFVAL{0}::={ rsAtmSubIfVccEntry 8}rsAtmSubIfVccMbs OBJECT-TYPESYNTAXInteger32UNITS"cells"MAX-ACCESSread-create
STATUScurrentDESCRIPTION"Maximum Burst Size, in cells, of this circuit.
This parameter is only required when rsAtmSubIfVccServiceCategory
is configured to have one of the following values:
nrtVbr
"DEFVAL{0}::={ rsAtmSubIfVccEntry 9}--
-- The ATM OAM Table
--rsAtmCircuitOamTable OBJECT-TYPESYNTAXSEQUENCEOF RsAtmCircuitOamEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"This table contains circuit OAM data for a PVC."::={ rsAtmSubIfLayer 4}rsAtmCircuitOamEntry OBJECT-TYPESYNTAX RsAtmCircuitOamEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"Each entry provides OAM data on an ATM PVC."INDEX{ rsAtmCircuitOamIfIndex, rsAtmCircuitOamVpi, rsAtmCircuitOamVci }::={ rsAtmCircuitOamTable 1}
RsAtmCircuitOamEntry ::=SEQUENCE{
rsAtmCircuitOamIfIndex
InterfaceIndex,
rsAtmCircuitOamVpi
Integer32,
rsAtmCircuitOamVci
Integer32,
rsAtmCircuitOamAdminStatus
INTEGER,
rsAtmCircuitOamLoopbackOperStatus
INTEGER,
rsAtmCircuitVcOamOperStatus
INTEGER,
rsAtmCircuitOamLoopbackFrequency
Integer32,
rsAtmCircuitInOamF5Cells
Counter32,
rsAtmCircuitInOamCellsDropped
Counter32,
rsAtmCircuitOutOamF5Cells
Counter32,
rsAtmCircuitInOamF5EndToEndLoopbackCells
Counter32,
rsAtmCircuitInOamF5SegmentLoopbackCells
Counter32,
rsAtmCircuitInOamF5AisCells
Counter32,
rsAtmCircuitInOamF5RdiCells
Counter32,
rsAtmCircuitOutOamF5EndToEndLoopbackCells
Counter32,
rsAtmCircuitOutOamF5SegmentLoopbackCells
Counter32,
rsAtmCircuitOutOamF5RdiCells
Counter32}rsAtmCircuitOamIfIndex OBJECT-TYPESYNTAXInterfaceIndexMAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"The ifIndex of the ATM subinterface."::={ rsAtmCircuitOamEntry 1}
rsAtmCircuitOamVpi OBJECT-TYPESYNTAXInteger32MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"The VPI of the ATM VCC used by this ATM interface and PVC."::={ rsAtmCircuitOamEntry 2}rsAtmCircuitOamVci OBJECT-TYPESYNTAXInteger32MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"The VCI of the ATM VCC used by this ATM interface and PVC."::={ rsAtmCircuitOamEntry 3}rsAtmCircuitOamAdminStatus OBJECT-TYPESYNTAXINTEGER{oamAdminStateDisabled(1),oamAdminStateEnabled(2)}MAX-ACCESSread-writeSTATUScurrentDESCRIPTION"The administrative state of OAM for the interface identified
by this entry."DEFVAL{1}::={ rsAtmCircuitOamEntry 4}rsAtmCircuitOamLoopbackOperStatus OBJECT-TYPE
SYNTAXINTEGER{oamOperStatusNotSupported(0),oamOperStatusDisabled(1),oamOperStatusSent(2),oamOperStatusReceived(3),oamOperStatusFailed(4)}MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The operational status of OAM for the interface identified
by this entry.
oamOperStatusNotSupported(0) - OAM not supported on this interface
oamOperStatusDisabled(1) - VC integrity disabled
oamOperStatusSent(2) - Loopback sent, awaiting response
oamOperStatusReceived(3) - Loopback response received, awaiting
frequency
oamOperStatusFailed(4) - Loopback response not received, or
invalid response received"::={ rsAtmCircuitOamEntry 5}rsAtmCircuitVcOamOperStatus OBJECT-TYPESYNTAXINTEGER{oamVcOperStateAisState(0),oamVcOperStateRdiState(1),
oamVcOperStateDownRetry(2),oamVcOperStateUpRetry(3),oamVcOperStateUp(4),oamVcOperStateDown(5),oamVcOperStateNotManaged(6)}MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The OAM VC operational status of this entry.
oamVcOperStateAisState(0) - AIS cell received or underlying physical
layer reporting transmission path AIS
oamVcOperStateRdiState(1) - RDI cell received
oamVcOperStateDownRetry(2) - OAM loopback failed, using retry frequency
to verify that the VC is really down.
oamVcOperStateUpRetry(3) - OAM loopback successful, using retry frequency
to verify that the VC is really up.
oamVcOperStateUp(4) - OAM loopback successful after up retry
verification
oamVcOperStateDown(5) - OAM loopback failed after down retry verification
oamVcOperStateNotManaged(6)- No verification via loopback cells being performed."::={ rsAtmCircuitOamEntry 6}rsAtmCircuitOamLoopbackFrequency OBJECT-TYPESYNTAXInteger32(0..600)
MAX-ACCESSread-writeSTATUScurrentDESCRIPTION"The OAM loopback frequency for the interface identified by this
entry."DEFVAL{10}::={ rsAtmCircuitOamEntry 7}rsAtmCircuitInOamF5Cells OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Received OAM F5 cells"::={ rsAtmCircuitOamEntry 8}rsAtmCircuitInOamCellsDropped OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Received OAM cells that were dropped."::={ rsAtmCircuitOamEntry 9}rsAtmCircuitOutOamF5Cells OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Transmitted OAM F5 cells"::={ rsAtmCircuitOamEntry 10}
rsAtmCircuitInOamF5EndToEndLoopbackCells OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Received OAM F5 end-to-end loopback cells"::={ rsAtmCircuitOamEntry 11}rsAtmCircuitInOamF5SegmentLoopbackCells OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Received OAM F5 segment loopback cells"::={ rsAtmCircuitOamEntry 12}rsAtmCircuitInOamF5AisCells OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Received OAM F5 AIS cells"::={ rsAtmCircuitOamEntry 13}rsAtmCircuitInOamF5RdiCells OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Received OAM F5 RDI cells"::={ rsAtmCircuitOamEntry 14}
rsAtmCircuitOutOamF5EndToEndLoopbackCells OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Transmitted OAM F5 end-to-end loopback cells"::={ rsAtmCircuitOamEntry 15}rsAtmCircuitOutOamF5SegmentLoopbackCells OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Transmitted OAM F5 segment loopback cells"::={ rsAtmCircuitOamEntry 16}rsAtmCircuitOutOamF5RdiCells OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Transmitted OAM F5 RDI cells"::={ rsAtmCircuitOamEntry 17}--
-- The ATM VPI/VCI Statistics Table
--rsAtmPvcStatisticsTable OBJECT-TYPESYNTAXSEQUENCEOF RsAtmPvcStatisticsEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"This table contains statistics for PVC entries."
::={ rsAtmIfLayer 3}rsAtmPvcStatisticsEntry OBJECT-TYPESYNTAX RsAtmPvcStatisticsEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"Each entry provides statistics on an ATM PVC."INDEX{ rsAtmPvcStatsIfIndex, rsAtmPvcStatsVpi, rsAtmPvcStatsVci }::={ rsAtmPvcStatisticsTable 1}
RsAtmPvcStatisticsEntry ::=SEQUENCE{
rsAtmPvcStatsIfIndex
InterfaceIndex,
rsAtmPvcStatsVpi
Integer32,
rsAtmPvcStatsVci
Integer32,
rsAtmPvcStatsInCells
Counter64,
rsAtmPvcStatsInCellOctets
Counter64,
rsAtmPvcStatsInPackets
Counter64,
rsAtmPvcStatsInPacketOctets
Counter64,
rsAtmPvcStatsOutCells
Counter64,
rsAtmPvcStatsOutCellOctets
Counter64,
rsAtmPvcStatsOutPackets
Counter64,
rsAtmPvcStatsOutPacketOctets
Counter64,
rsAtmPvcStatsInCellErrors
Counter32,
rsAtmPvcStatsinPacketErrors
Counter32,
rsAtmPvcStatsOutCellErrors
Counter32,
rsAtmPvcStatsOutPacketErrors
Counter32,
rsAtmPvcStatsInPacketDiscards
Counter32,
rsAtmPvcStatsInPacketOctetDiscards
Counter32}rsAtmPvcStatsIfIndex OBJECT-TYPESYNTAXInterfaceIndexMAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"The ifIndex of the ATM interface."::={ rsAtmPvcStatisticsEntry 1}rsAtmPvcStatsVpi OBJECT-TYPESYNTAXInteger32MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"The VPI of the ATM VCC used by this ATM interface and PVC."::={ rsAtmPvcStatisticsEntry 2}rsAtmPvcStatsVci OBJECT-TYPESYNTAXInteger32MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"The VCI of the ATM VCC used by this ATM interface and PVC."::={ rsAtmPvcStatisticsEntry 3}rsAtmPvcStatsInCells OBJECT-TYPE
SYNTAXCounter64MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Received cells."::={ rsAtmPvcStatisticsEntry 4}rsAtmPvcStatsInCellOctets OBJECT-TYPESYNTAXCounter64MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Received cells octets."::={ rsAtmPvcStatisticsEntry 5}rsAtmPvcStatsInPackets OBJECT-TYPESYNTAXCounter64MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Received AAL PDUs."::={ rsAtmPvcStatisticsEntry 6}rsAtmPvcStatsInPacketOctets OBJECT-TYPESYNTAXCounter64MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Received AAL PDU octets."::={ rsAtmPvcStatisticsEntry 7}rsAtmPvcStatsOutCells OBJECT-TYPESYNTAXCounter64
MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Transmitted cells."::={ rsAtmPvcStatisticsEntry 8}rsAtmPvcStatsOutCellOctets OBJECT-TYPESYNTAXCounter64MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Transmitted cell octets."::={ rsAtmPvcStatisticsEntry 9}rsAtmPvcStatsOutPackets OBJECT-TYPESYNTAXCounter64MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Transmitted AAL PDUs."::={ rsAtmPvcStatisticsEntry 10}rsAtmPvcStatsOutPacketOctets OBJECT-TYPESYNTAXCounter64MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Transmitted AAL PDU octets."::={ rsAtmPvcStatisticsEntry 11}rsAtmPvcStatsInCellErrors OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-only
STATUScurrentDESCRIPTION"Received cells dropped due to errors."::={ rsAtmPvcStatisticsEntry 12}rsAtmPvcStatsinPacketErrors OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Received packets dropped due to errors."::={ rsAtmPvcStatisticsEntry 13}rsAtmPvcStatsOutCellErrors OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Cells not transmitted due to errors."::={ rsAtmPvcStatisticsEntry 14}rsAtmPvcStatsOutPacketErrors OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Packets not transmitted due to errors."::={ rsAtmPvcStatisticsEntry 15}rsAtmPvcStatsInPacketDiscards OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-only
STATUScurrentDESCRIPTION"Received packets w/o errors discarded."::={ rsAtmPvcStatisticsEntry 16}rsAtmPvcStatsInPacketOctetDiscards OBJECT-TYPESYNTAXCounter32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Received bytes w/o errors discarded."::={ rsAtmPvcStatisticsEntry 17}--
-- The ATM Virtual Path Tunnel Table
--rsAtmVpTunnelTable OBJECT-TYPESYNTAXSEQUENCEOF RsAtmVpTunnelEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"This table contains entries for ATM VP Tunnels present in the system."::={ rsAtmIfLayer 4}rsAtmVpTunnelEntry OBJECT-TYPESYNTAX RsAtmVpTunnelEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"Each entry describes the characteristics of an ATM VP Tunnel."INDEX{ rsAtmVpTunnelIfIndex, rsAtmVpTunnelVpi }::={ rsAtmVpTunnelTable 1}
RsAtmVpTunnelEntry ::=SEQUENCE{
rsAtmVpTunnelIfIndex
InterfaceIndex,
rsAtmVpTunnelVpi
INTEGER,
rsAtmVpTunnelKbps
Integer32,
rsAtmVpTunnelRowStatus
RowStatus}rsAtmVpTunnelIfIndex OBJECT-TYPESYNTAXInterfaceIndexMAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"The ifIndex of the ATM interface. The value of this
object is the same as the rsAtmIfIndex object in
the rsAtmIfTable.
Entries in this table cannot be created unless the
underlying ATM interface entry is created first in
the rsAtmIfTable."::={ rsAtmVpTunnelEntry 1}rsAtmVpTunnelVpi OBJECT-TYPESYNTAXINTEGER(0..255)MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"The VPI value for this VP tunnel entry"::={ rsAtmVpTunnelEntry 2}rsAtmVpTunnelKbps OBJECT-TYPESYNTAXInteger32MAX-ACCESSread-createSTATUScurrentDESCRIPTION"The tunnel rate in Kilo bits/second (Kbps) for this entry"::={ rsAtmVpTunnelEntry 3}rsAtmVpTunnelRowStatus OBJECT-TYPESYNTAXRowStatusMAX-ACCESSread-createSTATUScurrentDESCRIPTION"Controls creation/deletion of entries in this table
according to the RowStatus textual convention,
constrained to support the following values only:
createAndGo
destroy
To create an entry in this table, the following
entry objects MUST be explicitly configured:
rsAtmVpTunnelRowStatus
rsAtmVpTunnelKbps
In addition, when creating an entry the following
conditions must hold:
A correponding rsAtmVpTunnelIfIndex value must have been
created in the rsAtmIfTable previously.
"::={ rsAtmVpTunnelEntry 4}-- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Notification control objects
-- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++-- No notifications are defined in this MIB. Placeholder follows.-- rsAtmTrapControl OBJECT IDENTIFIER ::= { rsAtmMIB 2 }-- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Notifications
-- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++-- No notifications are defined in this MIB. Placeholder follows.-- The following two OBJECT IDENTIFIERS are used to define SNMPv2
-- Notifications that are easily translated into SNMPv1 Traps.-- rsAtmTraps OBJECT IDENTIFIER ::= { rsAtmMIB 3 }
-- rsAtmTrapPrefix OBJECT IDENTIFIER ::= { rsAtmTraps 0 }-- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Conformance information
-- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++rsAtmConformance OBJECTIDENTIFIER::={ rsAtmMIB 4}rsAtmCompliances OBJECTIDENTIFIER::={ rsAtmConformance 1}rsAtmGroups OBJECTIDENTIFIER::={ rsAtmConformance 2}-- compliance statementsrsAtmCompliance MODULE-COMPLIANCESTATUScurrentDESCRIPTION"The compliance statement for entities which implement
the Redstone ATM MIB."MODULE-- this moduleMANDATORY-GROUPS{ rsAtmGroup, rsAtmAal5Group, rsAtmSubIfGroup }::={ rsAtmCompliances 1}-- units of conformancersAtmGroup OBJECT-GROUPOBJECTS{
rsAtmNextIfIndex,
rsAtmIfRowStatus,
rsAtmIfLowerIfIndex,
rsAtmIfOamCellRxAdminState,
rsAtmPvcStatsInCells,
rsAtmPvcStatsInCellOctets,
rsAtmPvcStatsInPackets,
rsAtmPvcStatsInPacketOctets,
rsAtmPvcStatsOutCells,
rsAtmPvcStatsOutCellOctets,
rsAtmPvcStatsOutPackets,
rsAtmPvcStatsOutPacketOctets,
rsAtmPvcStatsInCellErrors,
rsAtmPvcStatsinPacketErrors,
rsAtmPvcStatsOutCellErrors,
rsAtmPvcStatsOutPacketErrors,
rsAtmPvcStatsInPacketDiscards,
rsAtmPvcStatsInPacketOctetDiscards
}STATUScurrentDESCRIPTION"A collection of objects providing management of ATM interfaces
in a Redstone product."::={ rsAtmGroups 1}rsAtmAal5Group OBJECT-GROUPOBJECTS{
rsAtmAal5NextIfIndex,
rsAtmAal5IfRowStatus,
rsAtmAal5IfLowerIfIndex
}STATUScurrentDESCRIPTION"A collection of objects providing management of AAL5 interfaces
in a Redstone product."::={ rsAtmGroups 2}rsAtmSubIfGroup OBJECT-GROUP
OBJECTS{
rsAtmSubIfNextIfIndex,
rsAtmSubIfRowStatus,
rsAtmSubIfLowerIfIndex,
rsAtmSubIfVccRowStatus,
rsAtmSubIfVccVcd,
rsAtmSubIfVccType,
rsAtmSubIfVccServiceCategory,
rsAtmSubIfVccPcr,
rsAtmSubIfVccScr,
rsAtmSubIfVccMbs,
rsAtmSubIfVccRowStatus,
rsAtmSubIfVccVcd,
rsAtmSubIfVccType,
rsAtmSubIfVccServiceCategory,
rsAtmSubIfVccPcr,
rsAtmSubIfVccScr,
rsAtmSubIfVccMbs,
rsAtmCircuitOamAdminStatus,
rsAtmCircuitOamLoopbackOperStatus,
rsAtmCircuitVcOamOperStatus,
rsAtmCircuitOamLoopbackFrequency,
rsAtmCircuitInOamF5Cells,
rsAtmCircuitInOamCellsDropped,
rsAtmCircuitOutOamF5Cells,
rsAtmCircuitInOamF5EndToEndLoopbackCells,
rsAtmCircuitInOamF5SegmentLoopbackCells,
rsAtmCircuitInOamF5AisCells,
rsAtmCircuitInOamF5RdiCells,
rsAtmCircuitOutOamF5EndToEndLoopbackCells,
rsAtmCircuitOutOamF5SegmentLoopbackCells,
rsAtmCircuitOutOamF5RdiCells
}
STATUScurrentDESCRIPTION"A collection of objects providing management of ATM subinterfaces
in a Redstone product."::={ rsAtmGroups 3}END